ABSTRACT
The objective of the present
investigation is to assess the quality of the
water employed in three purposes, namely
ablution, household and washing, ascertain
the contamination problems that may
confront the consumers, and suggest
convenient reforms. The present study aims
also to enhance community participation in
the operation and maintenance of water and
sanitation facilities and to rationalize the use
of water. Nine ablution water, 7 household
water and 3 washing water samples were
randomly selected from different districts of
AlQurayyat. Out of 19 examined water
samples, 6 ablution water and 3 household
water samples were contaminated with
bacteria. However, water used in restaurants
was free of bacteria. The pH values were
located on the weak alkaline scale. Data
recorded indicate that 5 ablution water
samples, 2 restaurant water samples and
only one household water sample attained
TDS levels over 2000 mg/L. Other studied
water samples were freshwater; their
TDS levels ranged between 460 and 570
mg/L. The vast majority of the studied water
samples showed relatively high levels of
sulphate salts. The studied water samples
were either slightly chlorinated or non- chlorinated. They were clear or murky,
indicating variable degrees of
turbidity/transparency among studied water
samples. Nitrates showed marked variability
among studied water samples. The
maximum nitrate level was recorded for
ablution water (12.2 mg/L), while the
minimum value was documented for the
same water type (0.6 mg/L). Data obtained
revealed that nitrite levels were safe.
INTRODUCTION
Meeting the water demand of the
progressively growing population is the
greatest challenge facing the government in
Saudi Arabia as well as in other arid and
semi-arid countries worldwide (Al-Zahrani
Page 2 of 12
Journal for Studies in Management and Planning
Available at http://internationaljournalofresearch.org/index.php/JSMaP
e-ISSN: 2395-0463
Volume 01 Issue 04
May 2015
Available online: http://internationaljournalofresearch.org/ P a g e | 171
and Khodran, 2009, 2010). According to the
estimations of Al-Saud et al. (2011), the
overall water consumption in KSA is
approximately 611 m3
per second, 444m3
of
which (73%) are mined from non-renewable
water sources, namely groundwater aquifers.
Groundwater supplies a large proportion of
water globally (Gleeson et. al., 2013).
Groundwater aquifers have an enormous
storage capacity and are regarded as the
most relevant source of the clean, freshwater
in countries facing the threats of water
scarcity. Unfortunately, the supply of
groundwater is regularly decreasing, with
depletion occurring most prominently in
Asia and North America (Gleeson et. al.,
2013).Over the last decades, climatic
changes led to a dramatic depletion of the
renewable surface water. Poor management
policies and water consumption behavior
have deprived the community of such
enormous amounts of water. About two
billion people depend merely upon aquifers
for drinking water, and 40% of the world’s
food (Morris et. al., 2003).
The World Bank (2000) highlighted
the diverse water challenges in the Islamic
World. About 10 to 30% of the water losses
are contributed to leakage from faucets,
toilets, or plumbing fixtures in homes,
mosques, governmental buildings and public
institutions. Therefore, detecting and
repairing leaking fixtures forms a good
starting point for efficiency improvements.
Regular maintenance of water resources and
routine check of water facilities can save
huge amounts of water to be employed in
many purposes. Detecting water leaks in the
commercial and institutional buildings needs
continuous monitoring, overnight
monitoring, and water balances to determine
the level of leakage. Nowadays, the world is
shifting to keep balance between the water
supply and demand through the management
of water demand to achieve fair and
effective utilization of water.
The present study aims to evaluate
the physicochemical and bacteriological
properties of the water employed in three
purposes, namely ablution water, household
water and washing water in restaurants of
AlQurayyat. One of the objectives of the
present study is to raise the awareness of the
population about the community
participation in the maintenance of natural
water resources and the reduction of water
usage in order to overcome the water crisis
and keep water for the future generations.
MATERIALS AND METHODS
Nine ablution water, 7 household
water and 3 washing water samples were
Page 3 of 12
Journal for Studies in Management and Planning
Available at http://internationaljournalofresearch.org/index.php/JSMaP
e-ISSN: 2395-0463
Volume 01 Issue 04
May 2015
Available online: http://internationaljournalofresearch.org/ P a g e | 172
collected from different districts of
AlQurayyat. Water samples were collected
and processed according to the method
described in El−Naggar et al. (2015).
Chemical and bacteriological tests were
conducted at the laboratory of the water
purification plant in AlQurayyat. Data were
pooled to highlight the most common
features of each studied brand of water.
Total suspended solids (TSS) were
determined following Al-Mughalles et al.
(2012).A sterile, dry filter paper was
weighed (W1) and then placed on a vacuum
flask. 25 ml of the water sample was
dropped gently on the filter paper and a
suction pump was used to draw water across
the filter. The filter paper was then
transferred to a drying oven at 105°C
temperature for few minutes. The filter
paper holding solids was reweighed (W2)
and the net weight of the total suspended
solids was calculated according to the
following formula: [(W2 – W1) / 25] 106
.
HACH DR/5000 Portable
Spectrophotometer is the instrument was
used for the measurement of ammonia,
nitrate, nitrite, phosphate, iron, sulphate and
total chlorine. To determine the level of
ammonia in the studied water samples, 0.1
ml of the target water brand was gently
transferred in a clean and dry test tube and
two reagents, namely ammonia salicylate
and ammonia cyanurate were added. A
blank sample was prepared by mixing 0.1 ml
of distilled water with the above mentioned
reagents under similar conditions. To
estimate the value of nitrates in water, 1 ml
of each sample was injected in nitrate
reagent test tube and the instrument was
zeroed on the sample itself before reagent
addition. Nitrate reagent was added, then the
sample was put in the instrument and the
readings were taken after five minutes. An
amount of 25 ml of the waster sample was
placed in a glass cell and the same amount
of distilled water was put in another cell to
be the blank. 1 ml of two reagents, namely
Molybdate and Amino acid were added to
each cell.
RESULTS
Data concerning the
physicochemical and bacteriological
properties of the studied water types are
recorded in Tables 1, 2 and 3, respectively.
Figures 1, 2 and 3 show the levels of total
dissolved solids (TDS), turbidity and nitrates
in ablution water, respectively. It could be
noticed from Tables 1, 2 and 3 that the pH
values are located on the weak alkaline
scale. Except for a moderate alkaline (pH =
8.36) water sample collected from the