Page 1 of 7

Journal for Studies in Management and Planning

Available at

http://edupediapublications.org/journals/index.php/JSMaP/

e-ISSN: 2395-0463

Volume 02 Issue 10

October 2016

Available online:http://edupediapublications.org/journals/index.php/JSMaP/ P a g e | 1

Experimental study on the behaviour of

reinforced concrete thin-walled open

section compression members

1K.Nagaraju, 14FF1D8702, nagarajukaneti.ec@gmail.com

Mandava Institute of Engineering and Technology,

Vidya Nagar, Krishna District, Jaggayyapet, Andhra Pradesh, 521175

2Mr. D. Aditya Sairam, M-Tech. Assistant Professor.

Abstract:

Reinforced cement concrete wall panels are load

bearing integral structural elements of a building

system. The conventional wall panels are heavy,

reinforced at least with minimum percentage of

compression steel and possess handling and erection

problems. Thin-walled reinforced concrete wall

panels may eliminate the above shortcomings of the

conventional wall panels. They are also highly

suitable for modern construction as well as

economical. A thin-walled open section compression

member may be a suitable alternative to the

rectangular thin wall panels to overcome the

stability problems. Various geometrical sections like

channel, trapezoidal and curved sections can be used

in place of conventional wall panels. By virtue of

their geometrical shape, the slenderness effect, hence

the stability problem can be minimized if not

completely eliminated.

The main objective of the investigation is to

study the behaviour of reinforced concrete thin- walled open section compression members with web

stiffener in terms of load bearing capacity, lateral

deflection and failure mode and formulate suitable

design equations if the existing popular equations

are not compatible. Regression analysis based on

experimental data is carried out to suggest minimal

changes to the existing design equations of IS 456 –

2000 and ACI 318 – 1989.

Suitable buckling factors were identified,

optimized and incorporated in the above formulae

without altering the present form of these equations.

The compatibility of the modified IS and ACI

expressions has been tested for channel and

trapezoidal specimens and found to be satisfactory.

Finally comparison of theoretical ultimate loads of

empirical equation, modified ACI precast wall

equation and IS 456 – 2000 short column equation

were made. In order to simplify the modified IS short

column, buckling coefficient for channel and

trapezoidal sections have been computed. All the

three proposed equations are simple to use and yield

reliable estimation of ultimate load. Out of the three

suggested equations, the proposed empirical

equation is the most reliable, very simple to use with

buckling coefficient and nominally conservative in

estimating the ultimate failure load. The maximum

limits of slenderness ratio, height to flange width

ratio, height to thickness ratio and web width to

flange width ratio are suggested to exploit the

section efficiency and material strength effectively. .

Keywords

Reinforced Concrete Thin-Walled Open Section

Compression Members, Regression analysis,

Trapezoidal and Curved Sections.

1. Introduction

Poor people of rural India especially in backward

states and districts are living in kutcha houses or

makeshift shelters. Every year during monsoon

season and associated floods, their living conditions,

sufferings and loss of properties were reported quite

frequently. It is an issue to be addressed immediately

by all stake holders. Most of these houses are built

with mud walls reinforced with paddy straw or

thatched walls made with bamboo reapers and

coconut or palm leaves. The government endeavor in

providing low cost engineered structures is not as

successful as desired. The low cost houses executed

as pilot projects were found to be good and durable.

When the same is executed in rural areas through

contractors and NGO‟s, the ground realities and

ethical values of people involved in execution leaves

much to be desired in terms of quality and

workmanship. These projects in most of the states

are not yielding the expected change in the rural

society.

The solution lies in mass production of elements

of low cost houses in a mechanized and controlled

environment. One of the ways to infuse quality in

such constructions is to go for the mass production of

Page 2 of 7

Journal for Studies in Management and Planning

Available at

http://edupediapublications.org/journals/index.php/JSMaP/

e-ISSN: 2395-0463

Volume 02 Issue 10

October 2016

Available online:http://edupediapublications.org/journals/index.php/JSMaP/ P a g e | 2

precast elements of low cost houses as mentioned

above. These precast elements can be assembled at

the site of construction with bare minimum use of

cement and cement concrete, thereby eliminating

avenues of mass profits and unethical activities.

Precast roofing elements are already quite popular

among engineers and are available in wide variety of

structural forms and shapes. These precast roof

elements are thin, light in weight, easy to cast and

handle. Sufficient amount of theoretical procedures

are available to design them to any desired shape and

size. But the precast wall elements are not as popular

as they should be. The reasons may be the heavy

weight of elements, cumbersome construction joints,

handling difficulties and erection problems. These

conventional heavy wall panels also need

conventional foundation, thereby increase the cost of

house. All these inherent disadvantages of traditional

wall panels may be eliminated by reducing the

weight of wall panels without compromising on the

strength, stiffness and stability.

Thin-Walled Open Sections

An ideal precast concrete wall panel fulfilling the

dual functions of load bearing and space covering

need to be strong and light with a wide range of

aesthetic forms. In this context, the advanced

technologies such as high strength concrete,

mechanized casting and logistic techniques appear to

hold much potential in the development of reinforced

concrete thin-walled open section wall elements as a

practical proposition. Such load bearing concrete

thin-walls can even have all types of cross sections,

hitherto familiar to roof panels, such as angular,

folded, ribbed panel, trapezoidal, tee and curved

sections.

Fig 1: The building is covered by a thin six- petaled reinforced concrete shell.

2. Objective of our Research

The main objective of the investigation is to

establish thin-walled open section reinforced

concrete compression members with web stiffener as

a unique category of load bearing elements such as

reinforced concrete columns and to formulate design

expressions based on experiments. The investigation

is accordingly planned to include the following

aspects.

In the first phase of investigation, literature survey

was carried out covering the analytical and

experimental works so far conducted in the area of

the research. A critical review of the published

literature indicates that research work available on

thin-walled compression members is only related to

steel and research on reinforced concrete thin-walled

compression members is few. Moreover no literature

is available on reinforced concrete thin-walled open

section compression members with web stiffener.

However, review of published literature in the area

of the investigation either in reinforced concrete or

otherwise was taken up to identify the parameters of

investigation.

In the second phase of investigation, test

specimens were cast. Forty-eighty numbers of

channel section specimens and thirty-six numbers of

trapezoidal section specimens were cast. The height,

wall thickness, flange width and web width of the

test specimens were varied to effect the change in the

behaviour and load bearing capacity. All the test

specimens were tested to failure in loading frames.

First crack load, lateral deflection, failure load and

failure mode were studied. The modes of failure

were identified as torsional-flexural failure and

flexural failure.

In the third phase, the effect of vertical web

stiffener, increase in wall thickness, slenderness ratio

and height to flange width ratio were examined and

quantified in terms of lateral deflection, first crack

load, failure load, stiffness and ductility factors. A

series of graphs were drawn to illustrate the influence

of above parameters. It is observed that torsional

flexural failure takes place in channel specimens

with slenderness ratio less than 40 and beyond which

flexural failure takes place. The same limit in case of

trapezoidal specimens found to be 30. The above

limit in case of height to flange width ratio is 12 and

10 for channel and trapezoidal specimens

respectively. The web stiffener provided has

significantly enhanced the ultimate load in all the

four series of test specimens, but its contribution is

influenced by the slenderness ratio and height to

flange width ratio. The contribution of web stiffener

in reducing the ultimate lateral deflection is quite

effective but again highly influenced by the above

two parameters. The experimental data of one third

number of specimens were used for validation

purpose.

In the fourth phase, comparison of the

experimental failure load was made with the existing

equations of concrete wall design. Their

compatibility to the types of open sections tested has

been evaluated. Due to lack of compatibility and

Page 3 of 7

Journal for Studies in Management and Planning

Available at

http://edupediapublications.org/journals/index.php/JSMaP/

e-ISSN: 2395-0463

Volume 02 Issue 10

October 2016

Available online:http://edupediapublications.org/journals/index.php/JSMaP/ P a g e | 3

inconsistent estimation of failure load in different

ranges of slenderness ratio, it was decided to

formulate an empirical expression for open section

compression members without altering the basic

form of existing referred equations. The strength

ratio degradation of test specimens with increase in

slenderness ratio is the basis on which the empirical

equation is formulated. The validity of the proposed

empirical equation for other type of specimens has

been established using validation tests data. In the

second stage of this phase, regression analysis of

channel and trapezoidal specimens data have been

carried out using two exclusive PSO programs

written in MATLAB to suggest minimal

modification to the existing IS 456 – 2000 and ACI –

318 concrete column/wall formulae.

3. Experimental Design

This chapter presents a summary of the

experimental works conducted on thin-walled open

section reinforced concrete compression members

with vertical web stiffener. The experimental work

described in this chapter is the base of the present

investigation. The main objectives of the

experimental work are summarized as follows:

i. To get an insight of the behaviour and the

mode failure of thin-walled singly symmetric open

section reinforced concrete compression members

with vertical web stiffener under axial load.

ii. To find the influence of vertical web

stiffener, slenderness ratio and height to flange width

ratio on the behaviour and load bearing capacity.

iii. To find the beneficial effect vertical web

stiffener in reducing the torsional-flexural buckling

and flexural buckling.

iv. To find the compatibility/suitability of the

existing wall equations to predict the failure load of

thin-walled singly symmetric open section reinforced

concrete compression members with vertical web

stiffener under axial load.

v. To get adequate experimental data to

formulate necessary design expression empirically as

well as based on regression analysis.

vi. To verify and validate the proposed design

equations with additional experiments.

To achieve the above objectives, thin-walled

reinforced concrete singly symmetric open section

compression members made of channel and

trapezoidal sections were tested.

Test Specimens

The thin-walled reinforced concrete compression

members of above mentioned open sections tested in

the present study are classified under the following

two major categories as shown in Figure below:

 Series C - Compression members with

singly symmetric channel section.

 Series T - Compression members with

singly symmetric trapezoidal section.

Figure 2: 3D View and Sectional Plan of Channel

and Trapezoidal Test Specimens

The details of cross section of the test specimens

are shown in Figure below:

Figure 3: Cross Sectional Details of Channel and

Trapezoidal Test Specimens

The details of the channel section specimens