Pervious concrete pavementin corporating GGBS to alleviate

Pavement runoff and improve urbansustainability

P. PUGAZHENDHI

DEPARTMENT OF CIVIL ENGINEERING

PRIST (Deemed to be University), THANJAVUR

ABSTRACT

The use of pervious concrete pavement is significantly increasing due to the reduction of road

runoff andabsorption of noise. However, this type of pavement cannot be used forheavy traffic

due to a highamount of voids and consequently low strength of perviousconcrete. In this paper,

rice husk ash(RHA) was used in order to strengthen pozzolaniccement paste and the effect of

0%, 2%, 4%, 6%, 8%,10% and 12% weight percentages asa cement replacement in concrete

mixtures on the mechanical properties was studied.Moreover, 0.2% Vf of glass (where Vf is the

proportion of fiber volume to total volumeofconcrete), 0.5% Vf of steel and 0.3% Vf of

polyphenylene sulfide (PPS) fibers were usedto improve themechanical properties of the

pervious concrete. Also, several water tocement (w/c) ratios were made andthen, physical and

mechanical properties of hardenedconcrete, including porosity, permeability,

compressivestrength, tensile strength andflexural strength were investigated.

INTRODUCTION

Pervious concrete pavement is a unique and

effective means to meet growing

environmental demands. By capturing

rainwater and allowing it to seep into the

ground,pervious concrete is instrumental in

recharging groundwater, reducing

stormwater runoff,and meeting U.S.

Environmental Protection Agency (EPA)

stormwater regulations. Infact, the use of

pervious concrete is among the Best

Management Practices (BMP)recommended

by the EPA— and by other agencies and

geotechnical engineers across thecountry—

for the management of stormwater runoff on

a regional and local basis. Thispavement

technology creates more efficient land use

by eliminating the need for retentionponds,

swales, and other stormwater management

devices. In doing so, pervious concretehas

Page 2 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 908

the ability to lower overall project costs on a

first-cost basis. In pervious concrete,

carefully controlled amounts of water and

cementitious materialsare used to create a

paste that forms a thick coating around

aggregate particles. Apervious concrete

mixture contains little or no sand, creating a

substantial void content. Using sufficient

paste to coat and bind the aggregate particles

together creates a system of highly

permeable, interconnected voids that drains

quickly. Typically, between 15% and 25%

voids are achieved in the hardened concrete,

and flowrates for water through pervious

concrete typically are around 480 in./hr

(0.34 cm/s,which is 5 gal/ft2/ min or 200

L/m2/min), although they can be much

higher. Both thelow mortar content and high

porosity also reduce strength compared to

conventionalconcrete mixtures, but

sufficient strength for many applications is

readily achieved.

While pervious concrete can be used for a

surprising number of applications, its

primary use is in pavement. This report will

focus on the pavement applications of the

material, which also has been referred to as

porous concrete, permeable concrete, no- finesconcrete, gap-graded concrete, and

enhanced-porosity concrete.

Performance

After placement, pervious concrete has a

textured surface which many find

aesthetically pleasing and which has been

compared to a Rice Krispies® treat. Its low

mortar content and little (or no) fine

aggregate content yield a mixture with a

very lowslump, with a stiffer consistency

than most conventional concrete mixtures.

In spite of thehigh voids content, properly

placed pervious concrete pavements can

achieve strengths inexcess of 3000 psi (20.5

MPa) and flexural strengths of more than

500 psi (3.5 MPa).

This strength is more than adequate for most

low-volume pavement applications,

including high axle loads for garbage truck

and emergency vehicles such as fire trucks.

More demanding applications require

special mix designs, structural designs, and

placement techniques.

Pervious concrete is not difficult to place,

but it is different from conventional

concrete, and appropriate construction

techniques are necessary to ensure its

Page 3 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 909

performance. It has a relatively stiff

consistency, which dictates its handling and

placement requirements. The use of a

vibrating screed is important for optimum

density and strength. After screeding, the

material usually is compacted with a steel

pipe roller. There are no bullfloats,

darbies,trowels, etc. used in finishing

pervious concrete, as those tools tend to seal

the surface. Joints, if used, may be formed

soon after consolidation, or installed using

conventionalsawing equipment. (However,

sawing can induce raveling at the joints.)

Some perviousconcrete pavements are

placed without joints. Curing with plastic

sheeting must startimmediately after

placement and should continue for at least

seven days. Carefulengineering is required

to ensure structural adequacy, hydraulic

performance, andminimum clogging

potential. More detail on these topics is

provided in subsequentsections.

EXPERIMENTAL DESIGN

Permeability test

The best definition for a pervious and

permeable concrete is its permeabilityand

porosityproperties. Permeability is a

function how pores are related to each other.

To define the permeability of a material, the

permeability coefficientshould be

determined that is theamount of fluid

flowing through a unit areaper unit time

under a unit hydraulic gradient(that is

usually expressed in termsof centimeters per

second). Pervious concretepermeability can

be determinedusing the falling head tests. In

these tests, lateral surfaces

of the specimens arecovered and pressurized

water is applied on the upper surface of

thespecimens.When there is a steady stream

of water, the amount of water passing from a

certainheight within a specified time is

measured. The Average permeability

coefficientis is calculated according to Eq.

(1) based on Darcy’s law and layer flow

assumption. Theaverage results of the tests

on three cylindrical specimens with a

diameterand height of 100 mm are reported

as the permeability coefficient.

In this study four mix designs namely A, B,

C and D are made. Mixes A, B and

C,respectively have a w/c ratio of 0.27, 0.33

and 0.4 and each contains three types

offiber, 0.5% Vf steel, 0.2% Vf glass and

0.3% Vf PPS. Also in each of these

mixdesigns 0%,2%, 4%, 6%, 8%, 10%, and