Pervious concrete pavementin corporating GGBS to alleviate
Pavement runoff and improve urbansustainability
P. PUGAZHENDHI
DEPARTMENT OF CIVIL ENGINEERING
PRIST (Deemed to be University), THANJAVUR
ABSTRACT
The use of pervious concrete pavement is significantly increasing due to the reduction of road
runoff andabsorption of noise. However, this type of pavement cannot be used forheavy traffic
due to a highamount of voids and consequently low strength of perviousconcrete. In this paper,
rice husk ash(RHA) was used in order to strengthen pozzolaniccement paste and the effect of
0%, 2%, 4%, 6%, 8%,10% and 12% weight percentages asa cement replacement in concrete
mixtures on the mechanical properties was studied.Moreover, 0.2% Vf of glass (where Vf is the
proportion of fiber volume to total volumeofconcrete), 0.5% Vf of steel and 0.3% Vf of
polyphenylene sulfide (PPS) fibers were usedto improve themechanical properties of the
pervious concrete. Also, several water tocement (w/c) ratios were made andthen, physical and
mechanical properties of hardenedconcrete, including porosity, permeability,
compressivestrength, tensile strength andflexural strength were investigated.
INTRODUCTION
Pervious concrete pavement is a unique and
effective means to meet growing
environmental demands. By capturing
rainwater and allowing it to seep into the
ground,pervious concrete is instrumental in
recharging groundwater, reducing
stormwater runoff,and meeting U.S.
Environmental Protection Agency (EPA)
stormwater regulations. Infact, the use of
pervious concrete is among the Best
Management Practices (BMP)recommended
by the EPA— and by other agencies and
geotechnical engineers across thecountry—
for the management of stormwater runoff on
a regional and local basis. Thispavement
technology creates more efficient land use
by eliminating the need for retentionponds,
swales, and other stormwater management
devices. In doing so, pervious concretehas
Page 2 of 5
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 05
May 2019
Available online:https://ejbss.org/ P a g e | 908
the ability to lower overall project costs on a
first-cost basis. In pervious concrete,
carefully controlled amounts of water and
cementitious materialsare used to create a
paste that forms a thick coating around
aggregate particles. Apervious concrete
mixture contains little or no sand, creating a
substantial void content. Using sufficient
paste to coat and bind the aggregate particles
together creates a system of highly
permeable, interconnected voids that drains
quickly. Typically, between 15% and 25%
voids are achieved in the hardened concrete,
and flowrates for water through pervious
concrete typically are around 480 in./hr
(0.34 cm/s,which is 5 gal/ft2/ min or 200
L/m2/min), although they can be much
higher. Both thelow mortar content and high
porosity also reduce strength compared to
conventionalconcrete mixtures, but
sufficient strength for many applications is
readily achieved.
While pervious concrete can be used for a
surprising number of applications, its
primary use is in pavement. This report will
focus on the pavement applications of the
material, which also has been referred to as
porous concrete, permeable concrete, no- finesconcrete, gap-graded concrete, and
enhanced-porosity concrete.
Performance
After placement, pervious concrete has a
textured surface which many find
aesthetically pleasing and which has been
compared to a Rice Krispies® treat. Its low
mortar content and little (or no) fine
aggregate content yield a mixture with a
very lowslump, with a stiffer consistency
than most conventional concrete mixtures.
In spite of thehigh voids content, properly
placed pervious concrete pavements can
achieve strengths inexcess of 3000 psi (20.5
MPa) and flexural strengths of more than
500 psi (3.5 MPa).
This strength is more than adequate for most
low-volume pavement applications,
including high axle loads for garbage truck
and emergency vehicles such as fire trucks.
More demanding applications require
special mix designs, structural designs, and
placement techniques.
Pervious concrete is not difficult to place,
but it is different from conventional
concrete, and appropriate construction
techniques are necessary to ensure its
Page 3 of 5
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 05
May 2019
Available online:https://ejbss.org/ P a g e | 909
performance. It has a relatively stiff
consistency, which dictates its handling and
placement requirements. The use of a
vibrating screed is important for optimum
density and strength. After screeding, the
material usually is compacted with a steel
pipe roller. There are no bullfloats,
darbies,trowels, etc. used in finishing
pervious concrete, as those tools tend to seal
the surface. Joints, if used, may be formed
soon after consolidation, or installed using
conventionalsawing equipment. (However,
sawing can induce raveling at the joints.)
Some perviousconcrete pavements are
placed without joints. Curing with plastic
sheeting must startimmediately after
placement and should continue for at least
seven days. Carefulengineering is required
to ensure structural adequacy, hydraulic
performance, andminimum clogging
potential. More detail on these topics is
provided in subsequentsections.
EXPERIMENTAL DESIGN
Permeability test
The best definition for a pervious and
permeable concrete is its permeabilityand
porosityproperties. Permeability is a
function how pores are related to each other.
To define the permeability of a material, the
permeability coefficientshould be
determined that is theamount of fluid
flowing through a unit areaper unit time
under a unit hydraulic gradient(that is
usually expressed in termsof centimeters per
second). Pervious concretepermeability can
be determinedusing the falling head tests. In
these tests, lateral surfaces
of the specimens arecovered and pressurized
water is applied on the upper surface of
thespecimens.When there is a steady stream
of water, the amount of water passing from a
certainheight within a specified time is
measured. The Average permeability
coefficientis is calculated according to Eq.
(1) based on Darcy’s law and layer flow
assumption. Theaverage results of the tests
on three cylindrical specimens with a
diameterand height of 100 mm are reported
as the permeability coefficient.
In this study four mix designs namely A, B,
C and D are made. Mixes A, B and
C,respectively have a w/c ratio of 0.27, 0.33
and 0.4 and each contains three types
offiber, 0.5% Vf steel, 0.2% Vf glass and
0.3% Vf PPS. Also in each of these
mixdesigns 0%,2%, 4%, 6%, 8%, 10%, and