Page 1 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 845

Study On Interface Friction Between Construction Materials

R. PRAKASH

DEPARTMENT OF CIVIL ENGINEERING

PRIST(Deemed to be University), THANJAVUR

ABSTRACT

In this study, interface frictional resistance between organic soil and some of construction

material was investigated. Construction materials used in this work are concrete, metal, and

wood. Interface friction angle were determined for three different water contents values of

organic soil dry, 25%, 50%, and 75% respectively. Different face roughnesses were tested for

different water content. All tests were carried out using direct shear test device. Three different

normal forces were used and shear stress at 10% strain rate was taken as maximum shear stress.

Test results showed that water content of the organic soil, material type, and surface roughness

should be considered while selecting interface friction angle between organic soil and

construction materials.

INTRODUCTION

Organic soil is a mixture of fragmented

organic material formed in wetlands under

appropriate climatic and topographic

conditions and it is derived from vegetation

that has been chemically changed and

fossilized. This type of soils has low shear

strength and high compressive deformation

which often result in difficulties when

construction work is undertaken on the

deposit. Bearing capacity and settlement

problems are generally solved using pile

foundations or different improvement

methods. Pile foundation used in this type of

soil is generally friction piles where

loads transferred to soil through interface

friction between soil and pile material. One

of the important parameter for frictional

resistance is friction coefficientbetween pile

material and soil.

Many geotechnical problems involve

estimation of stresses transferred along the

interface between soils and solid surfaces.

Pile foundations and earth reinforcements

involve the estimation of interfacial friction

between soils and suchstructures. It is

Page 2 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 846

essential to determine the interface friction

angle between soil and pile material in order

to make a good estimation of the axial

capacity of the pile.

Also, knowledge of the interface friction

angle in the determination of the magnitude

and line of action of the wall reaction is

significant.

Various studies on interfacial friction

between soil and other materials were

carried out in the past. Different kinds of

apparatus were used in the literature to

determine interface friction angle between

soil and solid construction material such as

direct shear test apparatus, simple shear

apparatus, ring torsion apparatus, dual shear

apparatus, miniature pile test apparatus, and

soil-pile slip testsapparatus. Previous

researchers found that several factors

affecting the value of the interface friction

angle. Among those factors are: (i) soil

properties such as mineralogical

composition, density, grain shape, grain size

and gradation; and (ii) the properties of the

material surface such as hardness and

surface roughness. In this study, interfacial

friction between organic soil and some of

construction material was investigated using

direct shear box apparatus. Construction

materials used in this work are rough and

smooth concrete, smooth, rough, and painted

metal, and wood. Four different water

contents values of organic soil were used for

testing program. These are dry, %25, %50

and 75%. Interface friction angle was

measured using direct shear test device.

Tests were performed with locating

construction material at lower part of the

shear box and filling the upper part with

organic soil.

MATERAILS AND METHODS

Organic soil used in this experiment was

obtained from akarya region, Turkey. A

relatively uniformly graded organic soil is

used in the study. This organic soil is

classified as OH by Unified Soil

Classification System (USCS) and peat by

classification system suggested by Wüst.

Engineering properties of the organic soil.

Organic content was estimated according to

ASTM D2974.

Sieve analysis was carried out on ash and it

was found that ash contains 15% silt and

clay and 25% sand. Liquid limit of the

organic soil was estimated by fall cone test

according to BS1377 and found to be 125%.

Page 3 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 847

GEOMEMBRANE INTERFACE TEST

RESULTSPVC

Typical results relating 8 with horizontal

shearing displacement for the Ottawa sand- PVC interface.Tests conducted at 100 and

500 kPanormal stress are presented for shear

displacement from 0 to 25 mm. The 4c

forOttawa sand of 290 is also shown in this

figure. These profiles clearly indicate that at

both 100 and 500 kPa 8 is essentially equal

to O and that Spis mobilized by

approximately 2 - 3 mm relative

displacement along the interface. With

increasingshear displacement 8 values show

no appreciable reduction from the peak

condition and thus Sris approximately equal

to Sp.

No significant difference in measured 8

values with geo-membrane thickness was

observed in tests using either Ottawa or

Target sand in which 20 and 30 mil PVC

geo-membranes were used. Also specimen

configuration was found to have little effect

on S. Tests conducted with the PVC

specimen affixed to a rigid showed

essentially no difference in 8 during the

initialstages of shear when compared with

tests conducted in which the specimen was

positioned with a sand interface on both

surfaces. Typical data illustrating this

response are shown in Figure 4.4. It should

be noted however, that Section C type

specimens did show slightly increasing 8

values as relative displacement was carried

out to very high values. This can be

attributed to undulations or folds in this soft

PVC geo-membrane that developed during

these tests. Since foldscould not develop

during testing of Section B type specimens,

8 values in these testsremained constant at

large relative displacements.

Smooth HDPE

Typical profiles showing 8 as a function of

shearing displacement for theOttawa sand- HDPE interface. Tests conducted at 100

and750 kPa normal stress are presented for

horizontal displacements from 0 to 25mm.

Although these tests where continued for a

total of 350 mm no change in 8values

occurred past about 25 mm. For comparison

with the angle of shearingresistance of the

sand alone where O 21o

t = 290, Figure 4.6

clearly indicates that 8which ranges from

approximately 14 to 210 is substantially

below ktawa. This figurealso reveals that

there are distinct peak and residual interface

friction componentsthat are dependent on