Heavy Density Concretes For Nuclear Reactors

M. AMUTHA SURABI

DEPARTMENT OF CIVIL ENGINEERING

PRIST (Deemed to be University)

THANJAVUR - 613 403.

ABSTRACT

The performance requirements of the concrete of containment structures are mainly radiological

protection, structural integrity and durability, etc. For this purpose, high-performance heavy

density concrete with special attributes can be used. The aggregate of concrete plays an essential

role in modifying concrete properties and the physic mechanical properties of the concrete affect

significantly on its shielding properties. After extensive trials, 15 concrete mixes were prepared

by using the coarse aggregates of barite, magnetite, goethite and serpentine along with addition

of 10% silica fume (SF), 20% fly ash (FA) and 30% ground granulated blast-furnace slag

(GGBFS) to the total content of OPC for each mix. To achieve the high-performance concrete

(HPC- grade M60), All concrete mixes had a constant water/cement ratio of 0.35, cement content

of 450 kg/m3 and sand-to-total aggregate ratio of40%. Concrete density has been measured in

the case of fresh and hardened. The hardened concrete mixes were tested for compressive

strength at 7, 28 and 90 days.

INTRODUCTION

Concrete is by far the most widely used

material for reactor shielding due to its

cheapness and satisfactory mechanical

properties. It is usually a mixture of

hydrogen and other light nuclei, and nuclei

of fairly high atomic number (Ikraiam et al.,

2009). The aggregate component of concrete

that contains a mixture of many heavy

elements plays an important role in

improving concrete shielding properties and

therefore has good shielding properties for

the attenuation of photons and neutrons (El- Sayed, 2002; Akkurt et al., 2012). The

density of heavyweight concrete is based on

the specific gravity of the aggregate and the

properties of the other components of

concrete. Concretes with specific gravities

higher than 2600 kg/m3 are called

heavyweight concrete and aggregates with

specific gravities higher than 3000 kg/m3

are called heavyweight aggregate according

to TS EN 206-1 (2002). The aggregates and

other components are based upon the exact

application of the high density concrete.

Some of the natural minerals used as

aggregates in high density concrete are

hematite, magnetite, limonite, barite and

some of the artificial aggregates including

materials like steel punching and iron shot.

Minerals like bauxite, hydrous iron ore or

serpentine, all slightly heavier than normal

weight concrete can be used when high

fixed water content is required. It is essential

that heavy weight aggregates are inert with

respect to alkalis and free of oil, and foreign

coatings which may have undesired effects

on bonding of the paste to the aggregate

particles or on cement hydration. Presently,

heavyweight concrete is extensively used as

a shield in nuclear plants and radio therapy

Page 2 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 819

rooms, and for transporting, and storing

radioactive wastes. For this purpose,

concrete must have high strength and high

density. Heavyweight and high strength

concrete can be used for shielding purposes

if it meets the strength and radiation

shielding properties.

LITERATURE REVIEW

As mentioned above, concrete is versatile

and economical for shielding purposes and

that was the reason it was chosen to be used

as a shielding material in this study. The

difficulty in radiation shielding especially

from sources generated by the fission

process in the nuclear reactors is the

presence of different types of radiation in

the source. Thi implies that different

elements need to be combined to be able to

shield a single source.

Concrete is therefore important because of

its composite nature. This allows different

materials of different chemical compositions

to be combined to provide adequate

shielding. The composition of concrete has

an important effect on its shielding

properties.

For shielding of gamma rays, the density of

concrete is of most importance. Density can

be increased by incorporating heavy

aggregates in the concrete mixture. The

greater the density, the smaller the thickness

of concrete required (Kaplan, 1989). For

protection from neutron radiation the most

desirable composition of materials in a

concrete shield is more complicated

(Kaplan, 1989). Materials of low atomic

weight such as hydrogen usually in the form

of water are required to reduce fast neutrons

to slow neutrons of thermal energy.

Materials such as boron are required to

absorb thermal neutrons without producing

high-energy secondary gamma radiation in

the process (Kaplan, 1989).

Concrete for radiation shielding must

therefore in most cases be effective against

both gamma and neutron radiation. This

implies that heavy as well as light materials

are required for shielding purpose and a

compromise must therefore be made in the

composition of concrete for radiation

shielding. In addition to these shielding

requirements, a concrete radiation shield

also serve a structural function. This means

that mechanical properties that are important

structurally should also be satisfied.

The important properties of concrete which

need to be established during any radiation

shielding concrete development include:

 Ingredients

 Density

 Mechanical properties

 Shielding properties and

 Thickness of the shield

Determining the above parameters is a

challenge because the published literature on

the use of concrete for radiation shielding is

not extensive. In most cases when there is

literature on this topic, most of it is

presented primarily from the standpoint of

the shielding properties, with mechanical

characteristics of the concrete mixtures

which are normally of concern being

subordinated or completely omitted (Callan,

1962). Many of the studies, some which will

be extensively discussed in this section,

were found to be concerned primarily with

heavy concrete, most of which contained

iron ore as aggregate.

Page 3 of 5

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 820

No emphasis was placed on mechanical

properties of concrete and as a result many

problems arose with regard to cohesion,

workability, segregation and strength.

The other challenge presented by previously

studied heavy density concretes was that

most of the aggregates used were neither

available nor well-graded materials because

they were sourced directly from the mines

and their primary used was not for concrete

casting. The aggregates therefore contained

particle sizes which were not standardised

and not suitable for concrete casting. Callan

(1962) in his research also found that the

effects of the above omitted factors have not

been sufficiently discussed Just like any

other radiation shielding concrete design and

development, the major difficulty in this

research has been the lack of experimental

data for various conditions of radiation

energies and concrete types. The reason for

this is that most of the work in the nuclear

field is classified for security purposes. As a

result of this sensitive information

classification, it is found that technical

problems involved in the development of

HDSC mixtures are not extensively studied.

There are therefore areas that still require

attention in developing and designing

HDSC. These include (Callan, 1962):

 The question of segregation and

workability to provide a sound

homogenous mixture.

 The use of high water content that is

desirable for neutron shielding.

 Methods for placing in fairly

massive structures.

 Special cementing media.

 Effects of different additives such as

boron containing aggregates.

 Effect of high temperatures for

indefinite periods.

The above items can be better achieved

when knowledge from different domains

such as concrete technology, nuclear physics

and chemistry are integrated in developing

the concrete shielding medium. This is the

approach that was adopted in this research

after realisation of the above mentioned

difficulties.

EXPERIMENTAL STUDY

Workability of Fresh Concrete

The mixability, placeability, mobility,

compact ability and finish ability are

collectively known as workability. Slump

test is the easiest test that can be used in the

field forthe measurement of workability.

The slump of almost all the mixes was in the

range of

100 –120 mm. Table 4 depicts the slump

values of fresh concrete made with the

coarseaggregates of magnetite, barite,

goethite and serpentine. Evidently, the

concrete mixesmade obarite aggregate (B 1,

B2 and B3) give the highest slump values;

whereas theconcrete mixes containing

serpentine e aggregate (S1, S 2 and S3) give

the lowestvalues. The differences in slump

values are mainly due to the differences in

the rate of water absorption for the used

aggregates; these values a e 0.6 %, 0.83 %,

1.3 % and8.07 % for barite, magnetite,

serpentine and goethite, respectively

Density of Concrete

To call the concrete ashigh density concrete,

it must have unit weight more than 2600

kg/m3

as stated in (TS EN206-1 2002). In

general, the density of the concrete is

directly proportional to the specificgravity

Whoops!