Experimental Study On Performance Ofconcrete Under Fire

M. KANNAN

DEPARTMENT OF CIVIL ENGINEERING

PRIST (Deemed to be University), THANJAVUR

ABSTRACT

In India, design for fire safety follows a prescriptive code-based approach. Building codes detail

the types of construction materials, assemblies, and fire suppression systems that are required for

various building types. This prescriptive method has prevented structural engineers from

exposure to performance-based design approaches for fire safety. The motivation for this thesis

was to increase the awareness of the structural engineering field to the concepts behind structural

design for fire safety. Extensive research has been published on the performance of structural

steel in fire conditions, and simplified design tools already exist to describe its behavior. Such

tools do not exist for reinforced concrete structures. Research on concrete has been more

focused on material properties rather than structural performance.

INTRODUCTION

The objective of fire safety is to protect life

and property. Fires can occur at any time in

buildings, and the safety of occupants and

maintaining the integrity of the structure are

of majorimportance. Building codes

prescribe detailed measures for the fire

safety of structural membersbecause when

other means for containing a fire fail, such

as a fire suppression system

,structuralintegrity is the last line of defense.

Code-based structural fire safety

requirements refer to fireresistance which is

defined as the ability of a structural element

to maintain its load-bearingfunctions under

standard fire conditions. The fire resistance

rating of a structural member is theelapsed

time it exhibits resistance with respect to

structural integrity, stability, and

temperaturetransmission while exposed to

standard fire conditions. The measured fire

resistance of astructural member or

assembly is dependent on the geometry of

elements, materials used inconstruction, load

intensity, fire exposure, and the

characteristics of a given furnace. Testing

Page 2 of 6

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 803

forthe fire resistance of materials is done in

laboratories by exposing elements to fire

conditions andmonitoring their performance.

Numerical and analytical methods were

developed based on these fire tests as an

economicalalternative to laboratory testing.

Over the past two decades there has been a

widespread use offinite element programs to

determine structural performance in both

standard and natural fireconditions. The

above methods for predicting fire resistance

do not increase the awareness ofstructural

engineers to the concepts of design for fire

conditions. They are either prescriptive

intheir application to design or being

performed by the 2 materials and fire

communities whoseinterests are geared

towards properties of materials in fire

conditions and complicatedperformance- based analyses of structural elements. From

a design standpoint it is not sensible for a

practicing structural engineer to use finite

element software to analyze structural fire

performance because analyses are time

consuming and the use of these programs

requires a strong background in fire

protection engineering which most structural

engineers do not have.

The motivation for this thesis was to

increase the awareness of the structural

engineering field to the concepts behind

structural design for fire safety. The

development of simplified design toolsthat

predict the fire performance of structural

elements is of utmost importance to

practicingstructural engineers. These tools

address structural fire performance from an

applied designapproach similar to those

which exist for the effects of wind and

earthquake loads. Extensiveresearch has

been published on the performance of

structural steel in fire conditions,

andsimplified design tools already exist to

describe its behavior. However, such tools

do not existfor reinforced concrete structures

where research has been focused on the

material properties ofconcrete in fire

conditions rather than structural

performance.

Columns are the primary structural elements

that transfer the loads of a building

vertically to thefoundation. Reinforced

concrete is one of the two main material

types used for columns.

Numerous characteristics of a reinforced- concrete column affect the overall strength

of thecolumn: length, load eccentricity,

Page 3 of 6

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 05

May 2019

Available online:https://ejbss.org/ P a g e | 804

cross-section area, end connections, and

concrete and steelstrength.

When concrete columns are exposed to fire,

the material properties of concrete and the

reinforcing steel change as a result of the

temperature increases. The decreases in

yield strengthand modulus of elasticity

reduce the overall strength of the column.

Once the column strengthdecreases lower

than the applied load, the column will fail

either by crushing or by flexuralbuckling. In

structural fire performance testing, a column

is placed in a furnace and subjected toa

controlled fire while being loaded with a

prescribed force. The length of time from

thebeginning of fire exposure to failure is

the fire resistance rating of a column.

Achieving code-specified fire resistance

ratings is the goal in prescriptive-based

design fire protection. Fire and structural

code books such as the International

Building Code list types of occupancies and

the fire resistance ratings various structural

members should have. For reinforced- concrete columns, the minimum dimensions

for concrete cover and column dimensions

are listed for specific fire resistance ratings.

However, in the fire protection and

structural engineering industries,

prescriptive-based design is slowly being

replaced with a performance based design.

The major difference between the two types

of design is that performance-based requires

the demonstration of fire safety. Numerous

methods are available for assessing the fire

safety of a design. In the determination of

structural fire performance, three levels

exist: basichand calculations,

simplifiedmodels and iterative calculations

of strength, or complex computermodels.

Each level provides a measure of accuracy

to the overall results with computer

modelsproviding the most accurate

approximations.

METHODOLOGY

The motivation for this thesis was to

increase the awareness of the structural

engineering field tothe concepts behind

structural design for fire safety. Extensive

research has been published onthe

performance of structural steel in fire

conditions, and simplified design tools

already exist todescribe its behavior. Such

tools do not exist for reinforced concrete

structures. As suggested by the literature

review, the research on concrete has been

more focused on material propertiesrather