Page 1 of 6
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 05
May 2019
Available online:https://ejbss.org/ P a g e | 802
Experimental Study On Performance Ofconcrete Under Fire
M. KANNAN
DEPARTMENT OF CIVIL ENGINEERING
PRIST (Deemed to be University), THANJAVUR
ABSTRACT
In India, design for fire safety follows a prescriptive code-based approach. Building codes detail
the types of construction materials, assemblies, and fire suppression systems that are required for
various building types. This prescriptive method has prevented structural engineers from
exposure to performance-based design approaches for fire safety. The motivation for this thesis
was to increase the awareness of the structural engineering field to the concepts behind structural
design for fire safety. Extensive research has been published on the performance of structural
steel in fire conditions, and simplified design tools already exist to describe its behavior. Such
tools do not exist for reinforced concrete structures. Research on concrete has been more
focused on material properties rather than structural performance.
INTRODUCTION
The objective of fire safety is to protect life
and property. Fires can occur at any time in
buildings, and the safety of occupants and
maintaining the integrity of the structure are
of majorimportance. Building codes
prescribe detailed measures for the fire
safety of structural membersbecause when
other means for containing a fire fail, such
as a fire suppression system
,structuralintegrity is the last line of defense.
Code-based structural fire safety
requirements refer to fireresistance which is
defined as the ability of a structural element
to maintain its load-bearingfunctions under
standard fire conditions. The fire resistance
rating of a structural member is theelapsed
time it exhibits resistance with respect to
structural integrity, stability, and
temperaturetransmission while exposed to
standard fire conditions. The measured fire
resistance of astructural member or
assembly is dependent on the geometry of
elements, materials used inconstruction, load
intensity, fire exposure, and the
characteristics of a given furnace. Testing
Page 2 of 6
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 05
May 2019
Available online:https://ejbss.org/ P a g e | 803
forthe fire resistance of materials is done in
laboratories by exposing elements to fire
conditions andmonitoring their performance.
Numerical and analytical methods were
developed based on these fire tests as an
economicalalternative to laboratory testing.
Over the past two decades there has been a
widespread use offinite element programs to
determine structural performance in both
standard and natural fireconditions. The
above methods for predicting fire resistance
do not increase the awareness ofstructural
engineers to the concepts of design for fire
conditions. They are either prescriptive
intheir application to design or being
performed by the 2 materials and fire
communities whoseinterests are geared
towards properties of materials in fire
conditions and complicatedperformance- based analyses of structural elements. From
a design standpoint it is not sensible for a
practicing structural engineer to use finite
element software to analyze structural fire
performance because analyses are time
consuming and the use of these programs
requires a strong background in fire
protection engineering which most structural
engineers do not have.
The motivation for this thesis was to
increase the awareness of the structural
engineering field to the concepts behind
structural design for fire safety. The
development of simplified design toolsthat
predict the fire performance of structural
elements is of utmost importance to
practicingstructural engineers. These tools
address structural fire performance from an
applied designapproach similar to those
which exist for the effects of wind and
earthquake loads. Extensiveresearch has
been published on the performance of
structural steel in fire conditions,
andsimplified design tools already exist to
describe its behavior. However, such tools
do not existfor reinforced concrete structures
where research has been focused on the
material properties ofconcrete in fire
conditions rather than structural
performance.
Columns are the primary structural elements
that transfer the loads of a building
vertically to thefoundation. Reinforced
concrete is one of the two main material
types used for columns.
Numerous characteristics of a reinforced- concrete column affect the overall strength
of thecolumn: length, load eccentricity,
Page 3 of 6
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 05
May 2019
Available online:https://ejbss.org/ P a g e | 804
cross-section area, end connections, and
concrete and steelstrength.
When concrete columns are exposed to fire,
the material properties of concrete and the
reinforcing steel change as a result of the
temperature increases. The decreases in
yield strengthand modulus of elasticity
reduce the overall strength of the column.
Once the column strengthdecreases lower
than the applied load, the column will fail
either by crushing or by flexuralbuckling. In
structural fire performance testing, a column
is placed in a furnace and subjected toa
controlled fire while being loaded with a
prescribed force. The length of time from
thebeginning of fire exposure to failure is
the fire resistance rating of a column.
Achieving code-specified fire resistance
ratings is the goal in prescriptive-based
design fire protection. Fire and structural
code books such as the International
Building Code list types of occupancies and
the fire resistance ratings various structural
members should have. For reinforced- concrete columns, the minimum dimensions
for concrete cover and column dimensions
are listed for specific fire resistance ratings.
However, in the fire protection and
structural engineering industries,
prescriptive-based design is slowly being
replaced with a performance based design.
The major difference between the two types
of design is that performance-based requires
the demonstration of fire safety. Numerous
methods are available for assessing the fire
safety of a design. In the determination of
structural fire performance, three levels
exist: basichand calculations,
simplifiedmodels and iterative calculations
of strength, or complex computermodels.
Each level provides a measure of accuracy
to the overall results with computer
modelsproviding the most accurate
approximations.
METHODOLOGY
The motivation for this thesis was to
increase the awareness of the structural
engineering field tothe concepts behind
structural design for fire safety. Extensive
research has been published onthe
performance of structural steel in fire
conditions, and simplified design tools
already exist todescribe its behavior. Such
tools do not exist for reinforced concrete
structures. As suggested by the literature
review, the research on concrete has been
more focused on material propertiesrather
