Page 1 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2065

Integration of UPQC in Grid Connected PV System

by Power Angle Control Scheme

KATHA MUTHU.M

M.Tech – Power System Engineering,

PRIST Deemed University, Madurai, Tamilnadu

Abstract -The quality of electric power is greatly affected by the

proliferation of non-linear loads in electrical energy processing

applications like switched mode power supplies, electric motor

drives, battery chargers, etc., The custom power devices like

UPQC has gained more importance in power quality arena as it

gives the best solution for all power quality issues. UPQC is the

combination of both shunt and series active power filters

connected through a common DC link capacitor. The shunt

active power filter is the most corrective measure to remove the

current related problems, power factor improvement by

supplying reactive power and regulates DC link voltage. The

series APF acts as controlled voltage source and corrects voltage

related problems, like sag or swell, flickering, harmonics, etc.,.

As a combination of both of these, UPQC improves service

reliability. In the present work, shunt inverter control is based on

modified active ,reactive (p-q) power theory, uses High

selectivity filter (HSF) for reference current generation. The

series APF uses Power Angle Control (PAC) scheme for

compensating sag/swell, interruption and voltage related

problems along with sharing a part of load reactive power

demand with shunt APF and thus ease its loading and makes the

utilization of UPQC to be optimal. The topology uses three

phase three leg inverters for both shunt APF and series APF. The

gating signals were generated using Hysteresis controller. The

output of High step-Up DCDC Converter is used to work as DC

voltage source for both APFs. The input voltage for the

converter is provided by Photo Voltaic array incorporated with

P&O MPPT technique. The use of high step-up DC-DC

converter is for high voltage gain with better efficiency. The

present topology avoids the PLL in shunt active power filter.

Keywords: Power Angle Control, power quality, UPQC

I.INTRODUCTION

The term power quality got significant importance in

the electric power industry. The increasing application of

electronic equipment and distributed generation has led to the

Degradation of power quality by injecting harmonics, flicker and

voltage imbalance into the system. In addition, switching of

capacitor banks, lightning strikes on transmission lines and

various faults on the network also creates the power quality

issues such as transients, voltage sag or swell, interruptions,

etc.,.. The equipment which is increasingly susceptible to the

variations in Power Quality is termed as Sensitive Equipment or

Sensitive Load [4]. For proper load operation, it requires pure

sinusoidal voltage. With fast growing digital technology, the

devices that depending upon volatile memory chip for storages

are increasing and these are potentially at risk from power

quality events. To achieve this pure sinusoidal voltage and to

meet the power quality standards, it is necessary to use some

compensation techniques. Previously passive filters using tuned

LC components have been used to mitigate the harmonics,

which are low in cost, simple in configuration. But this has

drawbacks of fixed compensation, bulky in size and creates

resonance problems. Hence a modern solution is found in the

form of active power filtering. The shunt APF is suitable for

suppressing source current harmonics and the series APF is

suitable to compensate source voltage imperfections. The power

electronic controllers used in distribution system for the purpose

of supplying a level of reliability or power quality, which is

essentially required by sensitive load, is termed as custom power

devices [4]. These devices have the ability to perform voltage

regulation and current interruption functions within the

distribution system and hence it can be treated as power

conditioning device.

Page 2 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2066

II.POWER QUALITY

A sinusoidal signal of constant amplitude and of single

frequency which is constant is characterized as an ideal voltage

or current signal. Further it is required to maintain both voltage

and current in phase. Hence the quality of voltage quality or

current quality is the quality of voltage delivered to the

consumer or taken from the utility. Power quality problem is

nothing but the deviation of voltage/current from its ideal value.

Though the generator voltage is at or near pure sinusoidal, the

current passing through the load may create disturbance to it and

viz. voltage quality and current quality together is termed as

power quality. The process of supplying and grounding the

sensitive equipment with power such that the operation of such

equipment is satisfactory is nothing but power quality. Power

Quality has different meanings and significances according to

the requirement for which it has been defined. In the perspective

of designer or manufacturer, power quality is defined in a

manner that there should be no variation in voltage and no noise

generation in the grounding system. In view of utility engineer,

it is voltage availability or outage minutes. For the end users the

feasibility in using the available power for driving all kinds of

loads is termed as power quality. So a nonstandard voltage,

current or frequency that causes mal operation of end user

equipment is termed as power quality problem. Although the

entire power system has impact on power quality, most of the

problems occur in distribution system itself. The power quality

became significantly worse at points where the loads are

connected to the distribution grid

Power Quality Problems

1. Harmonic Distortion

2. Voltage Dips / Sags, and Surges / Swells

3. Unbalance

4. Flicker

5. Transients

III.UNIFIED POWER QUALITY CONDITIONER

The Unified Power Quality Conditioner is a custom power

device that is employed in the distribution system to mitigate the

disturbances that affect the performance of sensitive and/or

critical load [1]. It is a type of hybrid APF and is the only

versatile device which can mitigate several power quality

problems related with voltage and current simultaneously

therefore is multi functioning devices that compensate various

voltage disturbances of the power supply, to correct voltage

fluctuations and to prevent harmonic load current from entering

the power system. Fig. 1 shows the system configuration of a

single-phase UPQC. Unified Power Quality Conditioner

(UPQC) consists of two IGBT based Voltage source converters

(VSC), one shunt and one series cascaded by a common DC bus.

The shunt converter is connected in parallel to the load. It

provides VAR support to the load and supply harmonic currents.

Whenever the supply voltage undergoes sag then series

converter injects suitable voltage with supply [2]. Thus UPQC

improves the power quality by preventing load current

harmonics and by correcting the input power factor.

Block diagram of UPQC

Basic configuration of UPQC

The main components of a UPQC are series and shunt power

converters, DC capacitors, low-pass and high-pass passive

filters, and series and shunt transformers:

Series converter

It is a voltage-source converter connected in series with the AC

line and acts as a voltage source to mitigate voltage distortions.

It is used to eliminate supply voltage flickers or imbalance from

the load terminal voltage and forces the shunt branch to absorb

current harmonics generated by the nonlinear load. Control of

the series converter output voltage is usually performed using

sinusoidal pulse-width modulation (SPWM). The gate pulses

required for converter are generated by the comparison of a

fundamental voltage reference signal with a high-frequency

triangular waveform.

Shunt converter

Page 3 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2067

It is a voltage-source converter connected in shunt with the same

AC line and acts as a current source to cancel current distortions,

compensate reactive current of the load, and improve the power

factor. It also performs the DC-link voltage regulation, resulting

in a significant reduction of the DC capacitor rating. The output

current of the shunt converter is adjusted using a dynamic

hysteresis band by controlling the status of semiconductor

switches so that output current follows the reference signal and

remains in a predetermined hysteresis band.

IV.PHOTO VOLTAIC POWER GENERATING SYSTEM

Photo voltaic power generation uses solar cells to

convert solar irradiation into electrical energy. A grid connected

PV system converts light energy into electrical energy directly

and thus it mainly reduces the energy extracted from the

electrical utility. The development in power electronics and

material science has helped to develop compact but efficient

systems to withstand the high power demand. The PV cell

exhibits nonlinear I–V and P–V characteristics. The series

connected solar cells, which are basic building blocks of it,

forms a PV module. These PV modules are connected either in

series or in parallel depending upon its power rating forms a PV

array. The maximum power produced varies with temperature

and irradiance. Each cell has different current and voltage

maximum positions as these have non-linear characteristics. But

the power maximum point is unique, which mainly depends

upon Temperature and Irradiation. To track that maximum

power point, it is essential to use MPPT algorithm. The

maximum power point tracking (MPPT) algorithm is used to

extract the maximum power from PV panels from instantaneous

variations of irradiation, temperature and PV module

characteristics

P&O MPPT Technique

Maximum Power Point Tracking technique uses maximum

power transfer theorem, which states that, the output power is

maximum when thevinins impedance of circuit is equal to the

load impedance. Hence tracking the maximum power point is

nothing but tracking the impedance matching point. There are

many MPPT techniques available like perturb and observe

technique, Perturb and Observe (P&O), Incremental

Conductance method, Neural networks method, Fractional open

circuit voltage method, Fractional short circuit current method,

Fuzzy logic method [17], etc.,. The suitability of technique

depends on different parameters like cost, application, dynamic

performance and ease of implementation. Here we considered

P&O MPPT technique for our application. The P&O MPPT uses

only one voltage sensor. Hence it is cost effective and easy to

implement. The P&O MPPT algorithm states that when the

power converter operating duty cycle varies and the PV array

voltage is perturbed by a small increment and if the resulting

change in power, ΔP is positive, then it means that it is going in

the direction of MPP. Hence it keeps on perturbing in the same

direction. If ΔP is negative then it means it is going away from

the direction of MPP and the sign of perturbation is to be

changed. Thus this method uses the sign of perturbation and sign

of change in power to vary the duty cycle to be operated to track

the MPPT.

V.POWER ANGLE CONTROL SCHEME

The rating of series APF used in UPQC depends upon

the maximum percentage of sag/swell that it should compensate.

But these are of small duration issues. But the shunt APF

operates as long as the non-linear currents are drawn from the

source. It supplies the reactive power continuously, which leads

to increased utilization of it compared to series APF. The power

angle control scheme is mainly used to increase the utilization

factor of series APF without causing any additional burden on it.

Here the series APF is used to share a part of load reactive

power demand along with compensating voltage sag/swell by

creating a power angle difference between source voltage and

load voltage. The compensation of sag can be done by active

power approach or reactive approach or by both of these in

UPQC. Here this scheme uses both active and reactive power

approach to compensate the sag/swell by maintaining a constant

load voltage. The operation is better explained using the phasor

diagram shown in below