Page 1 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2058

Computer Aided Analysis and Design of Multi

Storeyed Buildings

P.SHANMUGANATHAN

M.Tech – Structural Engineering,

PRIST Deemed University, Madurai, Tamilnadu

Abstract - The principle objective of this project is to analyze

and design a multi-storeyed building [G +21 (3 dimensional

frame)] using STAAD Pro. The design involves load

calculations manually and analyzing the whole structure by

STAAD Pro. The design methods used in STAAD-Pro analysis

are Limit State Design conforming to Indian Standard Code of

Practice. STAAD.Pro features a state-of-the-art user interface,

visualization tools, powerful analysis and design engines with

advanced finite element and dynamic analysis capabilities. From

model generation, analysis and design to visualization and result

verification, STAAD.Pro is the professional’s choice. Initially

we started with the analysis of simple 2 dimensional frames and

manually checked the accuracy of the software with our results.

The results proved to be very accurate. We analyzed and

designed a G + 7 storey building [2-D Frame] initially for all

possible load combinations [dead, live, wind and seismic loads].

STAAD.Pro has a very interactive user interface which allows

the users to draw the frame and input the load values and

dimensions. Then according to the specified criteria assigned it

analyses the structure and designs the members with

reinforcement details for RCC frames. We continued with our

work with some more multi-storeyed 2-D and 3-D frames under

various load combinations. Our final work was the proper

analysis and design of a G + 21 3-D RCC frame under various

load combinations.

Key Words : STAAD Pro, multi-storeyed

I.INTRODUCTION

Our project involves analysis and design of multi- storeyed [G + 21] using a very popular designing software

STAAD Pro. We have chosen STAAD Pro because of its

following advantages:

 easy to use interface

 conformation with the Indian Standard Codes

 versatile nature of solving any type of problem

 Accuracy of the solution

STAAD.Pro features a state-of-the-art user interface,

visualization tools, powerful analysis and design engines with

advanced finite element and dynamic analysis capabilities. From

model generation, analysis and design to visualization and result

verification, STAAD.Pro is the professional’s choice for steel,

concrete, timber, aluminium and cold-formed steel design of low

and high-rise buildings, culverts, petrochemical plants, tunnels,

bridges, piles and much more.

STAAD.Pro consists of the following:

The STAAD.Pro Graphical User Interface: It is used to

generate the model, which can then be analyzed using the

STAAD engine. After analysis and design is completed, the GUI

can also be used to view the results graphically.

The STAAD analysis and design engine: It is a general-purpose

calculation engine for structural analysis and integrated Steel,

Concrete, Timber and Aluminium design.

To start with we have solved some sample problems using

STAAD Pro and checked the accuracy of the results with

manual calculations. The results were to satisfaction and were

accurate. In the initial phase of our project we have done

calculations regarding loadings on buildings and also considered

seismic and wind loads.

Structural analysis comprises the set of physical laws and

mathematics required to study and predicts the behaviour of

structures. Structural analysis can be viewed more abstractly as a

method to drive the engineering design process or prove the

soundness of a design without a dependence on directly testing

it. To perform an accurate analysis a structural engineer must

determine such information as structural loads, geometry,

support conditions, and materials properties. The results of such

an analysis typically include support reactions, stresses and

displacements. This information is then compared to criteria that

indicate the conditions of failure. Advanced structural analysis

may examine dynamic response, stability and non-linear

behavior.

II.LOADS CONSIDERED

Dead loads:

Page 2 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2059

All permanent constructions of the structure form the

dead loads. The dead load comprises of the weights of walls,

partitions floor finishes, false ceilings, false floors and the other

permanent constructions in the buildings. The dead load loads

may be calculated from the dimensions of various members and

their unit weights. the unit weights of plain concrete and

reinforced concrete made with sand and gravel or crushed

natural stone aggregate may be taken as 24 kN/m” and 25 kN/m”

respectively.

Imposed Loads

Imposed load is produced by the intended use or occupancy of a

building including the weight of movable partitions, distributed

and concentrated loads, load due to impact and vibration and

dust loads. Imposed loads do not include loads due to wind,

seismic activity, snow, and loads imposed due to temperature

changes to which the structure will be subjected to, creep and

shrinkage of the structure, the differential settlements to which

the structure may undergo.

Wind load:

Wind is air in motion relative to the surface of the earth.

The primary cause of wind is traced to earth’s rotation and

differences in terrestrial radiation. The radiation effects are

primarily responsible for convection either upwards or

downwards. The wind generally blows horizontal to the ground

at high wind speeds. Since vertical components of atmospheric

motion are relatively small, the term ‘wind’ denotes almost

exclusively the horizontal wind, vertical winds are always

identified as such. The wind speeds are assessed with the aid of

anemometers or anemographs which are installed at

meteorological observatories at heights generally varying from

10 to 30 metres above ground.

Design Wind Speed (V,)

The basic wind speed (V,) for any site shall be obtained

from and shall be modified to include the following effects to get

design wind velocity at any height (V,) for the chosen structure:

a)Risk level;

b)Terrain roughness, height and size of structure; and

c)Local topography.

It can be mathematically expressed as follows: Where:

V = Vb * kl * k* ks

Vb = design wind speed at any height z in m/s; kl = probability

factor (risk coefficient)

k = terrain, height and structure size factor and ks = topography

factor

Risk Coefficient

(kI Factor) gives basic wind speeds for terrain Category

2 as applicable at 10 m above ground level based on 50 years

mean return period. In the design of all buildings and structures,

a regional basic wind speed having a mean return period of 50

years shall be used.

Terrain, Height and Structure Size Factor (k, Factor)

Terrain - Selection of terrain categories shall be made

with due regard to the effect of obstructions which constitute the

ground surface roughness. The terrain category used in the

design of a structure may vary depending on the direction of

wind under consideration. Wherever sufficient meteorological

information is available about the nature of wind direction, the

orientation of any building or structure may be suitably planned.

Topography (ks Factor) - The basic wind speed Vb takes

account of the general level of site above sea level. This does not

allow for local topographic features such as hills, valleys, cliffs,

escarpments, or ridges which can significantly affect wind speed

in their vicinity. The effect of topography is to accelerate wind

near the summits of hills or crests of cliffs, escarpments or

ridges and decelerate the wind in valleys or near the foot of cliff,

steep escarpments, or ridges.

III.WORKING WITH STAAD.Pro

Input Generation:

The GUI (or user) communicates with the

STAAD analysis engine through the STD input file. That input

file is a text file consisting of a series of commands which are

executed sequentially. The commands contain either instructions

or data pertaining to analysis and/or design. The STAAD input

file can be created through a text editor or the GUI Modeling

facility. In general, any text editor may be utilized to edit/create

the STD input file. The GUI Modeling facility creates the input

file through an interactive menu-driven graphics oriented

procedure.

Types of Structures:

A STRUCTURE can be defined as an assemblage of

elements. STAAD is capable of analyzing and designing

structures consisting of frame, plate/shell and solid elements.

Almost any type of structure can be analyzed by STAAD.

A SPACE structure, which is a three dimensional

framed structure with loads applied in any plane, is the most

general.

A PLANE structure is bound by a global X-Y

coordinate system with loads in the same plane.

A TRUSS structure consists of truss members which

can have only axial member forces and no bending in the

members.

Page 3 of 7

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 2060

A FLOOR structure is a two or three dimensional

structure having no horizontal (global X or

Z) movement of the structure [FX, FZ & MY are

restrained at every joint]. The floor framing (in global X-Z

plane) of a building is an ideal example of a FLOOR structure.

Columns can also be modeled with the floor in a FLOOR

structure as long as the structure has no horizontal loading. If

there is any horizontal load, it must be analyzed as a SPACE

structure

Design for Flexure:

Design procedure is same as that for IS 456. However

while designing following criteria are satisfied as per IS-13920:

The minimum grade of concrete shall preferably be M20.

Steel reinforcements of grade Fe415 or less only shall be

used.

The minimum tension steel ratio on any face, at any

section, is given by:

ρmin = 0.24√fck/fy

 The maximum steel ratio on any face, at any section, is

given by ρmax = 0.025

 The positive steel ratio at a joint face must be at least

equal to half the negative steel at that face.

 The steel provided at each of the top and bottom face, at

any section, shall at least be equal to one-fourth of the

maximum negative moment steel provided at the face of

either joint.

Design for Shear:

The shear force to be resisted by vertical hoops is

guided by the IS 13920:1993 revision. Elastic sagging and

hogging moments of resistance of the beam section at ends are

considered while calculating shear force. Plastic sagging and

hogging moments of resistance can also be considered for shear

design if PLASTIC parameter is mentioned in the input file.

Shear reinforcement is calculated to resist both shear forces and

torsional moments.

Column Design:

Columns are designed for axial forces and biaxial

moments per IS 456:2000. Columns are also designed for shear

forces. All major criteria for selecting longitudinal and

transverse reinforcement as stipulated by IS: 456 have been

taken care of in the column design of STAAD. However

following clauses have been satisfied to incorporate provisions

of IS 13920:

 The minimum grade of concrete shall preferably be M20

 Steel reinforcements of grade Fe415 or less only shall be

used.

 The minimum dimension of column member shall not be

less than 200 mm. For columns having unsupported

length exceeding 4m, the shortest dimension of column

shall not be less than 300 mm.

 The ratio of the shortest cross-sectional dimension to the

perpendicular dimension shall preferably be not less than

IV.ANALYSIS OF G + 21 RCC FRAMED BUILDING USING

STAAD.Pro

Fig : plan of the G+21 storey building

All columns = 0.50 * 0.50 m (until ground floor) Columns at the

ground floor: 0.8 * 0.8 m

All beams = 0.3 * 0.5 m All slabs = 0.20 m thick

Terracing = 0.2 m thick avg. Parapet = 0.10 m thick RCC

Physical parameters of building:

Length = 4 bays @ 5.0m = 20.0m Width = 3 bays @ 5

m =15.0m

Height = 4m + 21 storeys @ 3.3m = 73.3m

(1.0m parapet being non- structural for seismic purposes, is not

considered of building frame height)

Live load on the floors is 2kN/m2 Live load on the roof is

0.75kN/m2

Grade of concrete and steel used: