Page 1 of 7
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 2058
Computer Aided Analysis and Design of Multi
Storeyed Buildings
P.SHANMUGANATHAN
M.Tech – Structural Engineering,
PRIST Deemed University, Madurai, Tamilnadu
Abstract - The principle objective of this project is to analyze
and design a multi-storeyed building [G +21 (3 dimensional
frame)] using STAAD Pro. The design involves load
calculations manually and analyzing the whole structure by
STAAD Pro. The design methods used in STAAD-Pro analysis
are Limit State Design conforming to Indian Standard Code of
Practice. STAAD.Pro features a state-of-the-art user interface,
visualization tools, powerful analysis and design engines with
advanced finite element and dynamic analysis capabilities. From
model generation, analysis and design to visualization and result
verification, STAAD.Pro is the professional’s choice. Initially
we started with the analysis of simple 2 dimensional frames and
manually checked the accuracy of the software with our results.
The results proved to be very accurate. We analyzed and
designed a G + 7 storey building [2-D Frame] initially for all
possible load combinations [dead, live, wind and seismic loads].
STAAD.Pro has a very interactive user interface which allows
the users to draw the frame and input the load values and
dimensions. Then according to the specified criteria assigned it
analyses the structure and designs the members with
reinforcement details for RCC frames. We continued with our
work with some more multi-storeyed 2-D and 3-D frames under
various load combinations. Our final work was the proper
analysis and design of a G + 21 3-D RCC frame under various
load combinations.
Key Words : STAAD Pro, multi-storeyed
I.INTRODUCTION
Our project involves analysis and design of multi- storeyed [G + 21] using a very popular designing software
STAAD Pro. We have chosen STAAD Pro because of its
following advantages:
easy to use interface
conformation with the Indian Standard Codes
versatile nature of solving any type of problem
Accuracy of the solution
STAAD.Pro features a state-of-the-art user interface,
visualization tools, powerful analysis and design engines with
advanced finite element and dynamic analysis capabilities. From
model generation, analysis and design to visualization and result
verification, STAAD.Pro is the professional’s choice for steel,
concrete, timber, aluminium and cold-formed steel design of low
and high-rise buildings, culverts, petrochemical plants, tunnels,
bridges, piles and much more.
STAAD.Pro consists of the following:
The STAAD.Pro Graphical User Interface: It is used to
generate the model, which can then be analyzed using the
STAAD engine. After analysis and design is completed, the GUI
can also be used to view the results graphically.
The STAAD analysis and design engine: It is a general-purpose
calculation engine for structural analysis and integrated Steel,
Concrete, Timber and Aluminium design.
To start with we have solved some sample problems using
STAAD Pro and checked the accuracy of the results with
manual calculations. The results were to satisfaction and were
accurate. In the initial phase of our project we have done
calculations regarding loadings on buildings and also considered
seismic and wind loads.
Structural analysis comprises the set of physical laws and
mathematics required to study and predicts the behaviour of
structures. Structural analysis can be viewed more abstractly as a
method to drive the engineering design process or prove the
soundness of a design without a dependence on directly testing
it. To perform an accurate analysis a structural engineer must
determine such information as structural loads, geometry,
support conditions, and materials properties. The results of such
an analysis typically include support reactions, stresses and
displacements. This information is then compared to criteria that
indicate the conditions of failure. Advanced structural analysis
may examine dynamic response, stability and non-linear
behavior.
II.LOADS CONSIDERED
Dead loads:
Page 2 of 7
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 2059
All permanent constructions of the structure form the
dead loads. The dead load comprises of the weights of walls,
partitions floor finishes, false ceilings, false floors and the other
permanent constructions in the buildings. The dead load loads
may be calculated from the dimensions of various members and
their unit weights. the unit weights of plain concrete and
reinforced concrete made with sand and gravel or crushed
natural stone aggregate may be taken as 24 kN/m” and 25 kN/m”
respectively.
Imposed Loads
Imposed load is produced by the intended use or occupancy of a
building including the weight of movable partitions, distributed
and concentrated loads, load due to impact and vibration and
dust loads. Imposed loads do not include loads due to wind,
seismic activity, snow, and loads imposed due to temperature
changes to which the structure will be subjected to, creep and
shrinkage of the structure, the differential settlements to which
the structure may undergo.
Wind load:
Wind is air in motion relative to the surface of the earth.
The primary cause of wind is traced to earth’s rotation and
differences in terrestrial radiation. The radiation effects are
primarily responsible for convection either upwards or
downwards. The wind generally blows horizontal to the ground
at high wind speeds. Since vertical components of atmospheric
motion are relatively small, the term ‘wind’ denotes almost
exclusively the horizontal wind, vertical winds are always
identified as such. The wind speeds are assessed with the aid of
anemometers or anemographs which are installed at
meteorological observatories at heights generally varying from
10 to 30 metres above ground.
Design Wind Speed (V,)
The basic wind speed (V,) for any site shall be obtained
from and shall be modified to include the following effects to get
design wind velocity at any height (V,) for the chosen structure:
a)Risk level;
b)Terrain roughness, height and size of structure; and
c)Local topography.
It can be mathematically expressed as follows: Where:
V = Vb * kl * k* ks
Vb = design wind speed at any height z in m/s; kl = probability
factor (risk coefficient)
k = terrain, height and structure size factor and ks = topography
factor
Risk Coefficient
(kI Factor) gives basic wind speeds for terrain Category
2 as applicable at 10 m above ground level based on 50 years
mean return period. In the design of all buildings and structures,
a regional basic wind speed having a mean return period of 50
years shall be used.
Terrain, Height and Structure Size Factor (k, Factor)
Terrain - Selection of terrain categories shall be made
with due regard to the effect of obstructions which constitute the
ground surface roughness. The terrain category used in the
design of a structure may vary depending on the direction of
wind under consideration. Wherever sufficient meteorological
information is available about the nature of wind direction, the
orientation of any building or structure may be suitably planned.
Topography (ks Factor) - The basic wind speed Vb takes
account of the general level of site above sea level. This does not
allow for local topographic features such as hills, valleys, cliffs,
escarpments, or ridges which can significantly affect wind speed
in their vicinity. The effect of topography is to accelerate wind
near the summits of hills or crests of cliffs, escarpments or
ridges and decelerate the wind in valleys or near the foot of cliff,
steep escarpments, or ridges.
III.WORKING WITH STAAD.Pro
Input Generation:
The GUI (or user) communicates with the
STAAD analysis engine through the STD input file. That input
file is a text file consisting of a series of commands which are
executed sequentially. The commands contain either instructions
or data pertaining to analysis and/or design. The STAAD input
file can be created through a text editor or the GUI Modeling
facility. In general, any text editor may be utilized to edit/create
the STD input file. The GUI Modeling facility creates the input
file through an interactive menu-driven graphics oriented
procedure.
Types of Structures:
A STRUCTURE can be defined as an assemblage of
elements. STAAD is capable of analyzing and designing
structures consisting of frame, plate/shell and solid elements.
Almost any type of structure can be analyzed by STAAD.
A SPACE structure, which is a three dimensional
framed structure with loads applied in any plane, is the most
general.
A PLANE structure is bound by a global X-Y
coordinate system with loads in the same plane.
A TRUSS structure consists of truss members which
can have only axial member forces and no bending in the
members.
Page 3 of 7
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 2060
A FLOOR structure is a two or three dimensional
structure having no horizontal (global X or
Z) movement of the structure [FX, FZ & MY are
restrained at every joint]. The floor framing (in global X-Z
plane) of a building is an ideal example of a FLOOR structure.
Columns can also be modeled with the floor in a FLOOR
structure as long as the structure has no horizontal loading. If
there is any horizontal load, it must be analyzed as a SPACE
structure
Design for Flexure:
Design procedure is same as that for IS 456. However
while designing following criteria are satisfied as per IS-13920:
The minimum grade of concrete shall preferably be M20.
Steel reinforcements of grade Fe415 or less only shall be
used.
The minimum tension steel ratio on any face, at any
section, is given by:
ρmin = 0.24√fck/fy
The maximum steel ratio on any face, at any section, is
given by ρmax = 0.025
The positive steel ratio at a joint face must be at least
equal to half the negative steel at that face.
The steel provided at each of the top and bottom face, at
any section, shall at least be equal to one-fourth of the
maximum negative moment steel provided at the face of
either joint.
Design for Shear:
The shear force to be resisted by vertical hoops is
guided by the IS 13920:1993 revision. Elastic sagging and
hogging moments of resistance of the beam section at ends are
considered while calculating shear force. Plastic sagging and
hogging moments of resistance can also be considered for shear
design if PLASTIC parameter is mentioned in the input file.
Shear reinforcement is calculated to resist both shear forces and
torsional moments.
Column Design:
Columns are designed for axial forces and biaxial
moments per IS 456:2000. Columns are also designed for shear
forces. All major criteria for selecting longitudinal and
transverse reinforcement as stipulated by IS: 456 have been
taken care of in the column design of STAAD. However
following clauses have been satisfied to incorporate provisions
of IS 13920:
The minimum grade of concrete shall preferably be M20
Steel reinforcements of grade Fe415 or less only shall be
used.
The minimum dimension of column member shall not be
less than 200 mm. For columns having unsupported
length exceeding 4m, the shortest dimension of column
shall not be less than 300 mm.
The ratio of the shortest cross-sectional dimension to the
perpendicular dimension shall preferably be not less than
IV.ANALYSIS OF G + 21 RCC FRAMED BUILDING USING
STAAD.Pro
Fig : plan of the G+21 storey building
All columns = 0.50 * 0.50 m (until ground floor) Columns at the
ground floor: 0.8 * 0.8 m
All beams = 0.3 * 0.5 m All slabs = 0.20 m thick
Terracing = 0.2 m thick avg. Parapet = 0.10 m thick RCC
Physical parameters of building:
Length = 4 bays @ 5.0m = 20.0m Width = 3 bays @ 5
m =15.0m
Height = 4m + 21 storeys @ 3.3m = 73.3m
(1.0m parapet being non- structural for seismic purposes, is not
considered of building frame height)
Live load on the floors is 2kN/m2 Live load on the roof is
0.75kN/m2
Grade of concrete and steel used: