Available online: https://ejbss.org/ P a g e | 2005
A Lyapunov-Function Based Control for a Three- Phase Shunt Hybrid Active Power Filter
MANI . D
M.TECH – Power System Engineering
PRIST Deemed University, Madurai, Tamilnadu
Abstract – The electronic and non-linear devices are
flexible, economical and energy efficient, they may
degrade power quality by creating harmonic currents
and consuming excessive reactive power. A family of
various shunt hybrid active power filters has been
explored in shunt and series configurations to
compensate for different types of nonlinear loads.
They provide controlled current injection to remove
harmonic current from the source side of electric
system and also can improve the power factor. In this
thesis, first three-phase system is implemented
without filter, its source current, compensating
current and THD values are studied, then PI control
strategy is applied then the differences in THD are
compared.A Lyapunov-function based control
algorithm for a SH-APF is proposed and implemented
to enhance its response to compensation of harmonics
of non-linear loads. The obtained results have
demonstrated the ability to compensate the current
harmonics effectively under distorted source
conditions. The fluctuation in the dc bus voltage of
the filter depends on the compensation speed of the
outer loop that regulates the dc bus voltage. A sudden
increase in the load power of this rectifier type non- linear load results in a decrease of the dc bus voltage
of the SH-APF system which recovers within a few
cycles.
I.INTRODUCTION
Over the past 100 years, the electric power
industry continues to shape and contribute to the
benefit, progression and technological advances of
the human race. The growth of electrical energy
consumption in the world has been nothing but
phenomenal. Electrical energy is the most efficient
and popular form of energy because it can be easily
converted to different forms of energies at high
efficiency and reasonable cost. The electric utility
industry can trace its beginnings to the early 1880s.
During that period several companies were formed
and installed water-power driven generation for the
operation of arc lights for street lighting; the first real
application for electricity in the United States. In
1882 Thomas Edison placed into operation the
historic Pearl Street steam-electric plant and the
pioneer direct current distribution system, by which
electricity was supplied to the business offices of
downtown New York. By the end of 1882, Edison’s
company was serving 500 customers that were using
more than 10,000 electric lamps. States. In 1882
Thomas Edison placed into operation the historic
Pearl Street steam-electric plant and the pioneer direct
current distribution system, by which electricity was
Page 2 of 7
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 2006
supplied to the business offices of downtown New
York. By the end of 1882, Edison’s company was
serving 500 customers that were using more than
10,000 electric lamps. There are four major reasons
for the increased concern:
1. The progeny of Newer-generation load equipment,
with microprocessor-based controls and power
electronic devices, is more sensitive to power quality
variations than was equipment used in the past.
2. The increasing emphasis on overall power system
efficiency has resulted in continued growth in the
application of devices such as high-efficiency,
adjustable-speed motor drives and shunt capacitors
for power factor correction to reduce losses. This is
resulting in increasing harmonic levels on power
systems and has many people concerned about the
future impact on system capabilities.
3. End users have an increased awareness of power
quality issues. Utility customers are becoming better
informed about such issues as interruptions, sags, and
switching transients and are challenging the utilities
to improve the quality of power delivered.
4. Many things are now interconnected in a network.
Integrated processes mean that the failure of any
component has much more important consequences.
Fig - Harmonically distorted waveform of Voltage
and Current
HARMONIC POWER FILTERS
Current source non-linear load
Thyristor converters are a common and typical source
of harmonic currents. Fig. 1(a) shows a thyristor
rectifier where a sufficient dc inductance produces a
dc current. Therefore, it is called a current-source
nonlinear load and represented as a current source
shown in Fig. 1(b). Similarly, diode rectifiers with a
sufficient dc inductance, a highly inductive load with
silicon-controlled rectifier (SCR) ac power control,
etc., are current-source nonlinear load
Voltage source non-linear load
Another common type of harmonic source is a diode
rectifier with smoothing dc capacitors, as shown in
Fig. 2(a). Therefore, the diode rectifiers behave like a
voltage source, rather than a current source. Fig. 2(b)
shows the equivalent circuit of the diode rectifier
system
Limitation of active power filter
There was a problem loading this page. Retrying...
Page 3 of 7
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 2007
Today modern active power filters are superior in
filtering performance, smaller in physical size and
more flexible in application compared to traditional
passive filters. Among the active power filter
configurations, shunt APF is the most important and
most widely used in industrial processes. It is
connected in parallel with the non-linear load, thus
can easily be adapted to existing plants. Main purpose
of the filter is to cancel the load current harmonics
injected to the supply but it can also implement
reactive power compensation and three phase currents
balancing [23]. However the APFs have still the
disadvantages of higher cost and complexity of
control
Limitation of Passive power filter
Initially, lossless passive filters (LC) have been used
to reduce harmonics and capacitors have been chosen
for power-factor correction of these nonlinear loads,
but passive filters have the demerits of fixed
compensation, large size and resonance with the
supply system.
Increasing demand of shunt hybrid active power filter
HYBRID active filters are considered one of the
favored options for improving power quality for a
number of considerations. Their topologies provide
inherent advantages which combine both passive and
active filter functions. Therefore, an improved- performance and cost-effective solution to harmonic
elimination is nowadays available for power quality
enhancement
SH-APF
The SH-AF consists of a low-rating active power
filter connected in series with a passive filter. The
SH-AF inherits the advantages of both active and
passive filters and thus constitutes a viable improved
approach for harmonic compensation and provides
cost-effective solutions. It damps resonances
occurring between line impedances and the passive
filter. On the other hand, the fundamental voltage
drops on the passive filter components allow the
shunt active power filter to operate with a
significantly lower dc-link voltage, which provides
significant reduction in the active filter power rating.
Although the passive filter compensates the fifth
harmonic, the active filter is controlled such as a
current-controlled voltage source aimed to
compensate for load harmonics and prohibiting them
from circulating into the ac mains. A diode bridge
rectifier with RL or RC load is considered as a
nonlinear load.
Actual work of an hybrid power filter is to inject the
harmonics to the supply which is out of phase with
the actual harmonics so as to cancel it.Fig.9 gives the
basic idea of the operation of hybrid power filter.
Figure: basic configuration of SH-APF
The Shunt hybrid Active power filter (SH-APF) is a
popular approach for cancelling the harmonics in
power system. The main component in the SH-APF is
the control unit. The control unit is mainly divided
into two parts as follows
There was a problem loading this page. Retrying...