Page 1 of 11
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 1824
Effective Hybrid Controller for Harmonics Elimination in Multilevel Inverter with
Unequal Dc Sources
SIVARAM .R
PG Student
PRIST Deemed to be University, Thanjavur
Abstract
Recent advancements in the field of power electronics have made possible the worldwide application of converters in dc power
source utilization, uninterruptible power supplies, electric motor speed control, switched mode power supplies, flexible
alternating current transmission systems devices including static synchronous compensator and their controls. Power
semiconductor devices such as converters have been emerged as powerful devices in the power industries. As such, harmonics
free output of inverters is assuming extreme importance. Over the past decades, depending upon the topologies and control
strategies, numerous optimization techniques have been proposed for desired output waveform. This paper presents a review of
optimization techniques used for multilevel inverters. The pros and cons of optimization techniques are discussed. The objective of
these optimization techniques is to find out the optimum firing angles of multilevel inverters, which results in minimum harmonics.
As a preferred option for proposed work, reduction of total harmonic distortion with the aid of particle swarm optimization
technique to multilevel inverters is suggested.
Keywords: Power Converters, Multilevel Inverters (MLI), Cascaded Hybrid Bridge (CHB), Modulation, Switching
Frequency, Harmonic Distortions.
1. INTRODUCTION
Ever since the advent of thyristors in mid 1960s, the field of
power electronics has become very popular in almost all
industrial applications; whether it may be electrical,
electronics, chemical, aerospace, textile etc. [1-3]. Power
converters have taken a very important place in the
industrial world. Initially the scope was limited up to two
level converters but nowadays multilevel converters such as
three levels, five levels and higher levels converters have
been designed depending upon the various topologies. The
main concern of system designers and application engineers
has been the task of appropriate designing of multilevel
converters which produce desired staircase wave with fewer
harmonics. This has been mainly due to the reason that on
increasing the number of levels, more harmonics are
introduced in the output of the inverters. The multilevel
inverter having harmonics free output attracted importance
in all industrial, commercial, domestic and defense
applications [4]. Hence, there has arisen the need for
suitable control strategies and optimization techniques to
achieve harmonics free output in multilevel inverters [5-7].
Neutral point clamped (NPC), flying capacitor (FC) and
cascaded hybrid bridge (CHB) are the three multilevel
converter topologies and well documented in the literature
[8]. A proper selection of topology using power
semiconductor devices forms the most ideal inverter for a
variety of industrial applications. More emphasis will be
given here to the features related to the CHB, since it is the
topology to be used in this paper for harmonic control. In the
late 1960s, with the series connected hybrid bridge
Page 2 of 11
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 1825
multilevel stepped waveform concept, CHB topology came
into existence [9]. Compared with NPC and FC topologies,
cascaded hybrid bridge converters require the minimum
number of components for producing the same number of
voltage levels because of elimination of clamping diodes
and voltage balancing capacitors. But CHB inverter needs
separate dc sources for each cell. After selection of
multilevel inverter topology; there is need to decide the
control or modulation strategies and optimization
techniques, which result in minimum total harmonic
distortion (THD) as mentioned in standards like IEEE-519,
EN 50160, IEC 61000-2-2, IEEE 61000-2-4 etc. [10].
This paper is arranged into six sections. Section I deals
with the introduction, gives the brief history of multilevel
inverter topologies, control strategies and optimization
techniques. Most widely used CHB topology is described
in section II. Suitable modulation techniques for designing
of multilevel inverters are mentioned in section III. Section
IV enlists the optimization techniques for finding the
optimum firing angles. Comparison of all the existing
optimization techniques has done in this section.
Challenges and future scope are mentioned in section V.
Finally conclusion has drawn in section VI.
2. CASCADED HYBRID
MULTILEVEL TOPOLOGY
Cascaded hybrid multilevel is an important topology of
multilevel inverters because of various advantages [11].
This topology includes the series of H-bridge inverter units
with separate dc sources for each unit. A n level
topology
Page 3 of 11
European Journal of Business &
Social Sciences
Available at https://ejbss.org/
ISSN: 2235-767X
Volume 07 Issue 04
April 2019
Available online: https://ejbss.org/ P a g e | 1826
requires 2(n-1) switches and (n-1)/2 isolated power supplies
per phase. Fig.1 shows one leg of 7 level CHB inverter.
Three different voltage levels are produced by each H- bridge, say bridge H1 will produce: +Vdc, 0 and –Vdc
voltages by different switching patterns of four switches i.e.
S1, S2, S3 and S4. In the same manner, other bridges also
produce the voltages. Each H-bridge produces the ac output.
The synthesized output voltage waveform is sum of all
individual H-bridges voltages.
Fig-1: Configuration of Seven Level Cascaded Inverter
The sinusoidal output voltage produced by cascaded
multilevel inverter depends upon the firing angles of
switching devices used in H-bridge. Switching devices of
each H-bridge are fired at different angles. For e.g. in 7 level
CHB inverter, three bridges i.e. H1, H2 and H3 are fired at
three different angles α1, α2 and α3 respectively. Firing
angles value are selected in such a way so that the inverter
produces the harmonics free sinusoidal waveform.
Fig.2 shows the output waveform for 7 level MLI. As the
output voltage generated by cascaded MLI depends on these
firing angles, the output voltage needs to vary from zero to
maximum (corresponding variation in modulation index is
from 0 to 1). Generally, these firing angles are calculated
with the aid of optimization techniques and are stored in a
look up table and accordingly switching devices are fired.
Fig-2: Typical Output Voltage Produced by Seven Level
Cascaded Inverter
3. MULTILEVEL INVERTER CONTROL
STRATEGIES
Another important feature of MLI is the various control
strategies applied to it [12]. The objective of these
modulation techniques is to get a switched stepped
waveform with fewer harmonics and losses. Fig.3 shows the
classification of modulation techniques based on the
switching frequency.
Numerous pulse width modulation (PWM) and space vector
control (SVC) strategies, which result in less complexity and
better output waveform have been reported in the literature
[13]. High power applications require fundamental or low
switching frequency modulation techniques to keep the
losses below the acceptable values. Another option is
selective harmonic control (SHC) technique. SHC strategy
includes selective harmonic elimination (SHE) and selective
harmonic mitigation (SHM). SHE technique is also known
as fundamental switching frequency method as per the
harmonic elimination theory proposed by Patel et al [14,
15],. In this control strategy, firing angles are selected such
that the THD is minimum in the output voltage waveform.