Page 1 of 11

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 1824

Effective Hybrid Controller for Harmonics Elimination in Multilevel Inverter with

Unequal Dc Sources

SIVARAM .R

PG Student

PRIST Deemed to be University, Thanjavur

Abstract

Recent advancements in the field of power electronics have made possible the worldwide application of converters in dc power

source utilization, uninterruptible power supplies, electric motor speed control, switched mode power supplies, flexible

alternating current transmission systems devices including static synchronous compensator and their controls. Power

semiconductor devices such as converters have been emerged as powerful devices in the power industries. As such, harmonics

free output of inverters is assuming extreme importance. Over the past decades, depending upon the topologies and control

strategies, numerous optimization techniques have been proposed for desired output waveform. This paper presents a review of

optimization techniques used for multilevel inverters. The pros and cons of optimization techniques are discussed. The objective of

these optimization techniques is to find out the optimum firing angles of multilevel inverters, which results in minimum harmonics.

As a preferred option for proposed work, reduction of total harmonic distortion with the aid of particle swarm optimization

technique to multilevel inverters is suggested.

Keywords: Power Converters, Multilevel Inverters (MLI), Cascaded Hybrid Bridge (CHB), Modulation, Switching

Frequency, Harmonic Distortions.

1. INTRODUCTION

Ever since the advent of thyristors in mid 1960s, the field of

power electronics has become very popular in almost all

industrial applications; whether it may be electrical,

electronics, chemical, aerospace, textile etc. [1-3]. Power

converters have taken a very important place in the

industrial world. Initially the scope was limited up to two

level converters but nowadays multilevel converters such as

three levels, five levels and higher levels converters have

been designed depending upon the various topologies. The

main concern of system designers and application engineers

has been the task of appropriate designing of multilevel

converters which produce desired staircase wave with fewer

harmonics. This has been mainly due to the reason that on

increasing the number of levels, more harmonics are

introduced in the output of the inverters. The multilevel

inverter having harmonics free output attracted importance

in all industrial, commercial, domestic and defense

applications [4]. Hence, there has arisen the need for

suitable control strategies and optimization techniques to

achieve harmonics free output in multilevel inverters [5-7].

Neutral point clamped (NPC), flying capacitor (FC) and

cascaded hybrid bridge (CHB) are the three multilevel

converter topologies and well documented in the literature

[8]. A proper selection of topology using power

semiconductor devices forms the most ideal inverter for a

variety of industrial applications. More emphasis will be

given here to the features related to the CHB, since it is the

topology to be used in this paper for harmonic control. In the

late 1960s, with the series connected hybrid bridge

Page 2 of 11

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 1825

multilevel stepped waveform concept, CHB topology came

into existence [9]. Compared with NPC and FC topologies,

cascaded hybrid bridge converters require the minimum

number of components for producing the same number of

voltage levels because of elimination of clamping diodes

and voltage balancing capacitors. But CHB inverter needs

separate dc sources for each cell. After selection of

multilevel inverter topology; there is need to decide the

control or modulation strategies and optimization

techniques, which result in minimum total harmonic

distortion (THD) as mentioned in standards like IEEE-519,

EN 50160, IEC 61000-2-2, IEEE 61000-2-4 etc. [10].

This paper is arranged into six sections. Section I deals

with the introduction, gives the brief history of multilevel

inverter topologies, control strategies and optimization

techniques. Most widely used CHB topology is described

in section II. Suitable modulation techniques for designing

of multilevel inverters are mentioned in section III. Section

IV enlists the optimization techniques for finding the

optimum firing angles. Comparison of all the existing

optimization techniques has done in this section.

Challenges and future scope are mentioned in section V.

Finally conclusion has drawn in section VI.

2. CASCADED HYBRID

MULTILEVEL TOPOLOGY

Cascaded hybrid multilevel is an important topology of

multilevel inverters because of various advantages [11].

This topology includes the series of H-bridge inverter units

with separate dc sources for each unit. A n level

topology

Page 3 of 11

European Journal of Business &

Social Sciences

Available at https://ejbss.org/

ISSN: 2235-767X

Volume 07 Issue 04

April 2019

Available online: https://ejbss.org/ P a g e | 1826

requires 2(n-1) switches and (n-1)/2 isolated power supplies

per phase. Fig.1 shows one leg of 7 level CHB inverter.

Three different voltage levels are produced by each H- bridge, say bridge H1 will produce: +Vdc, 0 and –Vdc

voltages by different switching patterns of four switches i.e.

S1, S2, S3 and S4. In the same manner, other bridges also

produce the voltages. Each H-bridge produces the ac output.

The synthesized output voltage waveform is sum of all

individual H-bridges voltages.

Fig-1: Configuration of Seven Level Cascaded Inverter

The sinusoidal output voltage produced by cascaded

multilevel inverter depends upon the firing angles of

switching devices used in H-bridge. Switching devices of

each H-bridge are fired at different angles. For e.g. in 7 level

CHB inverter, three bridges i.e. H1, H2 and H3 are fired at

three different angles α1, α2 and α3 respectively. Firing

angles value are selected in such a way so that the inverter

produces the harmonics free sinusoidal waveform.

Fig.2 shows the output waveform for 7 level MLI. As the

output voltage generated by cascaded MLI depends on these

firing angles, the output voltage needs to vary from zero to

maximum (corresponding variation in modulation index is

from 0 to 1). Generally, these firing angles are calculated

with the aid of optimization techniques and are stored in a

look up table and accordingly switching devices are fired.

Fig-2: Typical Output Voltage Produced by Seven Level

Cascaded Inverter

3. MULTILEVEL INVERTER CONTROL

STRATEGIES

Another important feature of MLI is the various control

strategies applied to it [12]. The objective of these

modulation techniques is to get a switched stepped

waveform with fewer harmonics and losses. Fig.3 shows the

classification of modulation techniques based on the

switching frequency.

Numerous pulse width modulation (PWM) and space vector

control (SVC) strategies, which result in less complexity and

better output waveform have been reported in the literature

[13]. High power applications require fundamental or low

switching frequency modulation techniques to keep the

losses below the acceptable values. Another option is

selective harmonic control (SHC) technique. SHC strategy

includes selective harmonic elimination (SHE) and selective

harmonic mitigation (SHM). SHE technique is also known

as fundamental switching frequency method as per the

harmonic elimination theory proposed by Patel et al [14,

15],. In this control strategy, firing angles are selected such

that the THD is minimum in the output voltage waveform.